For a US amateur station, the sequence is to inventory RF sources and places people can reach, test each source against the current exemption criteria, and evaluate exposure wherever an exemption is unavailable or uncertain. Compare the results with the limits that apply to the people exposed. If fields could exceed those limits in accessible areas, change the operation or access arrangements and verify the result. An exemption from routine evaluation is not permission to exceed an exposure limit.
Establish Which Rules Apply to Your Station
The starting point is 47 CFR § 97.13: the amateur licensee must ensure compliance with the FCC’s RF exposure requirements, including § 1.1307(b) and the mobile- and portable-device provisions where applicable. Section 1.1307(b) supplies the current routine-evaluation exemption criteria; § 1.1310 supplies the exposure limits. Use the current FCC rules in the eCFR for a decision, rather than treating an older example or calculator as the rule itself.
The distinction matters because screening, evaluation, and compliance are different questions. An exemption answers whether a source must undergo a routine environmental evaluation to demonstrate compliance. It does not remove the obligation to comply with the applicable RF exposure limits. If a source does not qualify for an exemption, an evaluation provides a basis for comparing exposure at relevant locations with those limits; failing an exemption screen does not, by itself, mean a limit has been exceeded.
The FCC’s amended rules took effect on May 3, 2021. They replaced service-specific evaluation exemptions with formula-based criteria that apply across services. Existing operations covered by the transition had until May 3, 2023, to comply, while a modification that could affect exposure became subject to the new rules when made. The FCC’s 2021 notice explains those dates; it is not a substitute for applying the current rule. In particular, do not use a former amateur-service exemption or a 50-watt power-only shortcut to decide whether a station is exempt today.
Consider a hypothetical fixed station with one or more antennas and RF sources. Before choosing a formula, its operator lists each source and operating band, the maximum settings that might be used, the antennas and their locations, and the areas people can actually reach. That last inventory includes the operator’s position, places immediate household members may occupy, and neighboring or other accessible areas. It does not assume that everyone stands at the usual operating position, or that a property boundary by itself settles the exposure question.
For this station, the operator would first screen the relevant source or sources under § 1.1307(b). Where a screen cannot establish exemption, the operator would select an evaluation method suited to the antenna and accessible geometry. Only then could the operator compare exposure for each group of people and decide whether anything must change. Without the station’s power, operating pattern, antenna characteristics, and geometry, the example cannot establish a safe distance or a compliance verdict.
Screen Each RF Source for a Routine-evaluation Exemption
Start with the inputs the rule actually uses. Record the source’s frequency, its available maximum time-averaged power, and, for routes that call for it, its effective radiated power (ERP). Establish the minimum separation R between any part of the radiating structure and any part of a nearby person’s body. The closest relevant position may be beside, below, or behind an antenna rather than at the operator’s desk. For the Table 1 route, express R in meters and frequency f in MHz.
Section 1.1307(b)(3) offers alternative single-source exemption routes, not a general rule that low transmitter output guarantees exemption:
- No more than 1 mW: A source whose available maximum time-averaged power is no more than 1 mW can use this route regardless of separation distance. The rule restricts combining this exemption with other exemption criteria: it may be used with the provision identified in § 1.1307(b)(3)(ii)(A), not freely mixed with whichever screen is most favorable to another source. If more than one source is involved, follow the rule’s applicable multiple-source provisions rather than declaring the whole station exempt because one source meets 1 mW.
- The Pth route: Compare the greater of available maximum time-averaged power and ERP with the rule’s threshold. This route applies only from 0.5 to 40 cm separation and 0.3 to 6 GHz, inclusive. Use the formula in the official § 1.1307(b)(3)(i)(B)(3)(i)(B)); do not substitute a threshold from another route or extend this one beyond its stated distances and frequencies.
- The Table 1 ERP route: Compare the source’s ERP in watts with the threshold for its frequency row below. This route requires R ≥ λ/2π, where λ is the free-space wavelength in meters. If the nearest accessible body position does not satisfy that distance condition, the table does not establish an exemption there.
| Source frequency, f (MHz) | Maximum ERP for the Table 1 exemption (watts) |
|---|---|
| 0.3–1.34 | 1,920 × R² |
| 1.34–30 | 3,450 × R² / f² |
| 30–300 | 3.83 × R² |
| 300–1,500 | 0.0128 × R² × f |
| 1,500–100,000 | 19.2 × R² |
These are exemption thresholds, not permissible exposure levels. They depend on the minimum relevant separation, so the hypothetical station cannot obtain a Table 1 answer without identifying its accessible geometry. A threshold from the right frequency row is useful only after its distance prerequisite and ERP input are established.
ERP also needs the right gain convention. For this rule, it uses the antenna’s maximum far-field power gain relative to a dipole multiplied by the maximum delivered time-averaged power; the rule calls for summing ERP over two polarization components when both are present. That is not the same input label as the gain in dBi requested by ARRL’s fixed-station calculator. A value prepared for one task should not be copied into the other without applying the correct definition.
Finally, look beyond an individually passing antenna. For fixed RF sources operating in the same time-averaging period, § 1.1307(b)(3)(ii) provides a multiple-source screen based on their fractional contributions to applicable thresholds. The applicable sum must be no more than 1. Determine which sources can contribute in the same period and use that provision’s conditions; a successful single-source check alone does not resolve their combination.
For the hypothetical station, an unknown closest separation, unsupported ERP, an inapplicable distance or frequency range, or an unresolved multiple-source sum means the screen has not established exemption. The next step is a technically valid exposure evaluation—not a guessed pass and not an assumption that exceeding an exemption threshold necessarily means exceeding an exposure limit. ARRL’s guidance likewise frames the choice as establishing exemption under the new criteria or performing an evaluation.
Evaluate Accessible Areas When Exemption Is Unavailable or Uncertain
Return to the station inventory and mark the closest accessible parts of each antenna and the locations a body could occupy near them. Check the operator’s position, household areas, neighboring areas, and other places people may reach. Account for antenna directionality: a location farther away in a strong lobe may need attention as well as the nearest position. Include other RF sources that may operate during the relevant period. The aim is to evaluate actual accessible situations, not produce one clearance radius for every direction.

For each source and operating case, assemble the information needed by the chosen method:
- Frequency and antenna information: Identify the operating frequency, antenna location, gain, pattern, and the accessible positions being tested. A directional antenna may require more than one position or calculation to represent its lobes.
- Power delivered to the antenna: Use the relevant maximum operating setting and account for feed-line loss. ARRL describes its calculator’s antenna-power input as transmitter power minus feed-line losses. Keep this evaluation input distinct from the rule’s definitions used for exemption screening.
- Documented time and mode assumptions: Identify the modes and settings that could produce the greatest relevant time-averaged exposure, along with the transmit/receive pattern used for comparison. Mode duty cycle affects average output during transmission; the split between transmitting and receiving also affects average output over time. Neither justifies inserting an unverified universal “voice” or transmit percentage.
- People and simultaneous sources: Identify which accessible positions are public locations and which, if any, are immediate-household locations eligible for a different limit. Note sources that can contribute together rather than evaluating each only in isolation.
If using ARRL’s fixed-station calculator instructions, enter the kind of gain that tool requests: its calculator labels antenna gain in dBi and asks for frequency separately. For time assumptions, its current instructions assign 100% duty cycle to an always-on carrier, such as tune-up, and to unknown or otherwise unlisted modes as a worst-case catch-all. They list 50% specifically for heavily processed conversational SSB. That entry is not a measured constant for every SSB signal or every voice transmission; an operating assumption must fit the documented case being evaluated.
An evaluation need not automatically involve measuring fields. ARRL identifies valid calculations, including simple formulas or antenna modeling, and measurements as possible approaches; it says measurements are not inherently required. The method must nevertheless answer the question posed by the station’s accessible positions. A simple fixed-station power-density calculation can estimate exposure where its assumptions apply, and ARRL notes that multiple runs may be needed for antenna lobes and directionality. A model or measurement may be needed when the simple calculation cannot represent the geometry.
Check the method’s distance limits before using the calculator. ARRL says its calculator should not be used when an antenna is less than 20 cm from a person. Its 2021 FAQ also places the simple calculation beyond the applicable near-field boundary and points to other methods, such as antenna modeling, for closer accessible areas. More than 20 cm of separation therefore does not, on its own, establish that the simple far-field approach is valid. If accessible geometry—including a small-loop situation—defeats those assumptions, use technically valid modeling or measurement instead, and seek qualified help where necessary.
Do not transfer a fixed-station field estimate to a different device question. A portable device requires the applicable portable-device SAR evaluation provisions in § 2.1093; a fixed-station power-density calculator is not a portable SAR test. Section 1.1310 permits the applicable maximum permissible exposure, or MPE, provisions in place of whole-body SAR for environmental evaluation from 300 kHz through 6 GHz, but expressly excepts portable devices as defined in § 2.1093.
For the hypothetical station, this stage ends with a justified method and results for its accessible positions—not a certification inferred from calculator output alone. If an antenna position falls outside a simple method’s scope, the operator changes methods or obtains suitable help before relying on a comparison.
Compare Results with the Limits for the People Exposed
Assign the person category before comparing numbers. Under § 97.13, exposure of nearby people who are not immediate household members must be evaluated against the general population/uncontrolled limits. That includes neighbors, regardless of whether the operator has discussed the antenna with them. For members of the licensee’s immediate household, the rule permits use of occupational/controlled limits only if both the licensee and those household members have accessed appropriate training and information. Merely sharing a residence, seeing the antenna, or knowing that transmission occurs does not establish that condition. Otherwise, use the public limits for them too.
Next choose the frequency-dependent limit and averaging condition in current § 1.1310. There is no single power-density figure for all amateur bands. As a bounded illustration, in the 30–300 MHz MPE rows, the public power-density limit is 0.2 mW/cm², with the table specifying an averaging time of less than 30 minutes; the controlled row gives 1.0 mW/cm², with less than 6 minutes. Those figures are exposure limits for that frequency range, not exemption thresholds, and should not be carried into another frequency row. The same tables also specify electric- and magnetic-field-strength limits where applicable.
The averaging comparison must reflect operation rather than a favorable instant. Section 1.1310 allows a shorter exposure above a listed level only when its average over a period no longer than the applicable table time remains at or below the applicable limit. Use the station’s supported mode, power, and transmit/receive assumptions to assess the relevant period. A brief high-power transmission is not automatically acceptable, just as assuming continuous transmission is not a substitute for documenting a different operating case when that case matters to the result.
Apply the right device and exposure method too. The MPE provisions can be used for the specified environmental exposure evaluations, including accessible fixed-station areas within their applicable scope. Portable-device cases covered by § 2.1093 follow its SAR provisions instead. A power-density result for an accessible place near a fixed antenna cannot establish SAR compliance for a handheld operated close to a person.
Then account for sources that may contribute at the same time. The exemption rules explicitly recognize combined contributions from fixed sources operating in the same averaging period; likewise, an individual result cannot by itself answer whether the exposure at a location from relevant simultaneous sources is acceptable. Compare the appropriately assessed exposure at each accessible place with the limit for the people who can be there. Do not use a household result as the answer for a neighboring location.
At the hypothetical station, the operator would first compare evaluated public locations—including neighboring areas—with the applicable public limits and averaging conditions. A household location could instead be compared with controlled limits if the § 97.13 training-and-information condition is met; otherwise it remains a public-limit comparison. The operator would consider relevant combined exposure in each case. The sequence identifies what must be checked without pretending that an unspecified antenna, operating pattern, or location has passed.
Correct Possible Exceedances and Keep the Basis Current
Section 97.13 sets a clear action trigger: if a routine environmental evaluation indicates RF fields could exceed § 1.1310 limits in accessible areas, the licensee must act to prevent human exposure to those fields. Do not treat uncertainty about who might enter an area as proof that it is inaccessible. At the hypothetical station, a possible exceedance might call for lower operating power, different transmit timing, an altered antenna arrangement, or a change to access. Which response works depends on the affected location and limit. Reevaluate that location—and any others the change affects—before relying on the correction.
If the chosen correction is restricted access around a fixed RF source, consult the applicable, category-specific mitigation provisions in § 1.1307(b)(4)(ii)–(vi). They require measures to the extent necessary for compliance and address matters including access restrictions, disclosure of areas where limits are exceeded, and an RF safety plan; apply the sign and training measures relevant to the actual category and circumstances. A warning sign alone, or an unsupported expectation that nobody enters, is not a universal solution. If those arrangements cannot be implemented appropriately, the conservative alternative is to change operation or access until the general-population limits are met at the affected accessible places, then verify again.
Keep a reviewable basis for the decision: the source inventory; maximum settings and operating assumptions; the exemption route used or evaluation method selected; accessible locations and person categories; applicable limits; results; and checks after any correction. ARRL recommends keeping evaluation information, while noting that the rules do not impose a blanket requirement that amateur operators keep evaluation records. Nor should a particular worksheet be represented as something every station must file with the FCC. The rule does require supporting technical information showing the basis for exemption or evaluation when the FCC requests it; the FCC’s 2021 transition notice said it created no additional filing beyond ordinary renewals or modifications for the parties it addressed.
Reopen the basis when exposure-relevant facts change. ARRL specifically identifies increased transmitter power, a new antenna, or a moved antenna as reasons to rescreen or evaluate. A changed operating pattern or newly accessible position can likewise change the inputs and comparison, even if the equipment stays in place. The durable result is not a completed worksheet: it is a station whose sources have been screened, whose uncertain or nonexempt exposures have been validly evaluated, whose accessible people are compared with the right limits, and whose necessary corrections have been verified.